27
EN
Control functions
The thermostat
can regulate the tempera-
ture in three dierent ways. This enables
the comfort temperature and any ooring
temperature requirements to be combined.
How the settings are adjusted is descri-
bed on the next page
.
Floor thermostat (F) - A sensor in the oor
measures the temperature and then regu-
lates the heating accordingly.
This is the
factory setting.
Room thermostat (R) - The thermostat
has built-in sensors for measuring the
room’s temperature and controlling the
heating.
Room and oor thermostat (R&F) - The
built-in sensor regulates the room tem-
perature and the sensor in the oor func-
tions as a oor temperature limiter. The
limitation can be set to between 25°C
and 45°C. The factory setting is 35 °C.
Important
In rooms with large windows that are ex-
posed to solar insolation, we recommend
the Room and oor thermostat function.
In rooms with wooden ooring, the
Room and oor thermostat function
must always be used.